Location:
Pneumatic Model – Insufficient Pressure / Weak Downstroke

Pneumatic Model – Insufficient Pressure / Weak Downstroke

2026-08-06 12:30
StepOperationCriterion
Step 1: Check CompressorRead the output pressure gauge on the compressorBelow 0.4MPa → insufficient pressure, increase compressor output to above 0.6MPa
Step 2: Check Air HosesApply soapy water to all joints and look for bubblesBubbles appear → air leak, tighten joints or replace hoses
Step 3: Check Pressure RegulatorCheck the regulator setting on the machineBelow 0.4MPa → adjust to 0.5-0.6MPa
Step 4: Check CylinderListen for abnormal noise or air leakage during cylinder operationHissing sound → cylinder seal ring is worn, contact manufacturer for seal replacement

One-Sentence Summary: It's always one of three things – weak compressor, leaking air hoses, or improper regulator adjustment.

Prevention: Check air hose joints with soapy water weekly. Drain the compressor regularly (moisture in compressed air will corrode the pneumatic system).


Recent Updates

Hotline:+86 13738991178
Email:luguow@yizhaomachine.com
WhatsApp:+86 15307796319